Epion reports first peer-reviewed phase 3 results on EpiSmart system for keratoconus

This is editorially independent content
8 min read

Epion Therapeutics, Inc. recently announced the publication of the first peer-reviewed scientific paper on its phase 3 clinical program of the EpiSmart Epithelium-On Crosslinking (CXL) System for the treatment of keratoconus.

Let’s start with Epion.

Headquartered in Burlington, Massachusetts, Epion is a late-stage, private biotech company developing a minimally-invasive treatment for ectatic corneal disease.

More specifically: The company’s goal in preventing vision loss is by targeting keratoconus, a common form of ectatic corneal disease.

And this treatment?

The EpiSmart Epithelium CXL System is a drug-device combination intended to be utilized at the initial disease diagnosis to prevent further disease progression.

This investigational system is comprised of three components:

  • a drug (RiboStat)
  • a drug delivery device (EpiPrep)
  • an ultra-violet A (UVA) device

Tell me about each of these.

We’ll start with EpiPrep, a disposable wand designed to enhance epithelial permeability without disruption.

  • Its design involves a disposable loading sponge that maintains drug concentration during stromal loading

As for the drug itself (RiboStat) and UVA device, these consist of a high concentration of riboflavin that drives diffusion into the stroma—and reportedly has the ideal tonicity and pH for penetration through the intact epithelium.

  • The drug’s sodium iodide formulation also:
    • removes peroxide to protect the cornea and riboflavin
    • catalyzes the most favorable reactions for efficient CXL

And how do they work together?

This is where the EpiSmart technology comes into play, in which it treats both eyes minimally-invasively while simultaneously removing the need for additional penetration.

Plus, it also:

  • causes no disruption to the epithelium
  • requires no need for continuous dosing or supplemental oxygen

Noted. So what is EpiSmart’s regulatory status?

Epion received Fast Track Designation from the FDA in October 2025, allowing for the company potentially being eligible for more frequent interactions with the FDA as well as a rolling review of its application package (once submitted).

What this means: A rolling review would allow Epion to submit its new drug application (NDA) for regulatory approval in stages rather than all at once.

  • And if all relevant criteria are met, the company may also receive an accelerated approval timeline and priority review.

Give me some more details on the phase 3 program.

The program consists of two identical, multicenter, randomized, double-masked, sham-controlled, parallel-group phase 3 trials (Apricity-A [NCT06100939; n=396] and Apricity-B [NCT06100952; n=398]) evaluating the efficacy and safety of epithelium-on corneal CXL in participants aged 8 to 45 years with keratoconus.

Participants were randomized 1:1 to receive EpiSmart or a sham procedure, with simultaneous bilateral treatment performed when appropriate.

Note: Epion announced this past June that the final patient had completed the last study visit in the phase 3 trials.

What are the main outcome measures?

  • Primary endpoint: best spectacle-corrected distance visual acuity (BSCDVA) assessed using Early Treatment Diabetic Retinopathy Study (ETDRS) VA testing charts from baseline to 12 months
  • Secondary endpoint: vision-related quality of life as assessed by the National Eye Institute 25-Item Visual Function Questionnaire (NEI-VFQ-25) from baseline to 12 months

Isn’t there another epithelium-on treatment option for keratoconus?

Indeed. In October 2025 (a busy month for the company), the FDA approved Glaukos’ Epioxa for the treatment of keratoconus.

Since then, the company has received a permanent J-code and reported positive 3-year data from the phase 3 trials.

How does Epioxa compare to EpiSmart?

By regulatory status: Epioxa is now FDA-approved while EpiSmart remains an investigational device.

  • How the systems work:
    • Epioxa uses two formulations (Epioxa HD and Epioxa), given one after the other, followed by UV activation in an oxygen-enriched environment. That extra oxygen comes from Boost Goggles with the O2n System, and the riboflavin is activated by pulsed UV-A light at higher intensity.
    • EpiSmart doesn’t use supplemental oxygen and instead utilizes a chemical reaction to generate oxygen within the cornea (see above). It is also designed for simultaneous treatment of both eyes across a wide range of keratoconus severity, including at diagnosis without documented progression; however this could change in the final label.

And based on clinical evidence?

Epioxa has undergone evaluations in two phase 3 trials with over 400 patients; these studies met their primary endpoints for improvement in maximum corneal curvature (Kmax) at 12 months.

Comparatively, EpiSmart’s evaluations have consisted of two phase 3 trials with almost 800 patients and a BSCDVA at 12 months as the primary endpoint.

The takeaway: Glaukos’ trials used corneal curvature as the measure of success while Epion’s trials are built around a vision outcome—making direct comparison between the two currently difficult.

  • See here for a recent commentary reviewing the two technologies.

With that out of the way, let’s move on to the paper.

Published in the journal Cornea, the study was conducted in collaboration with the Corneal Image Analysis Reading Center (CIARC) of the UH Eye Institute in Cleveland, Ohio, and evaluated the impact of keratoconus disease severity on corneal endothelial cell density (ECD).

A subcohort of 254 participants (aged 15-45, 66.9% male, 33.1% female; 477 eyes) at 11 clinical sites enrolled in the aforementioned phase 3 study of epi-on CXL in keratoconus and underwent specular microscopy of the central endothelium in both eyes at baseline before treatment.

  • The baseline ECD: 2,802 ± 285 cells/mm2 (range: 1,868–3,650 cells/mm2)

Tell me more.

  • ECD was graded by two image analysts from a central image analysis reading center with adjudication if ECD differed ≥5%
  • The correlation by linear regression was evaluated between ECD with:
    • Pentacam Belin/Ambrósio display final “D”
    • Anterior radius of curvature (ARC)
    • Minimal corneal thickness (MinCT)
    • Posterior elevation at the thinnest point (PETP) percentage of thickness increase (PTI)

And the findings?

In bivariate correlation analysis, ECD negatively correlated with:

  • age (r = −0.19, P < 0.01)
  • final “D” (r = −0.25, P < 0.01)
  • PETP (r = −0.23, P < 0.01)

Conversely: ECD was positively correlated with ARC (r = 0.20, P < 0.01) and MinCT (r = 0.19, P < 0.01).

Anything else?

ECD significantly decreased with age (β = −8.89, P < 0.01), resulting in:

  • increasing final “D” (β = −8.68, P < 0.01)
  • increasing PETP (β = −1.86, P < 0.01)
  • decreasing ARC (β = 60.95, P < 0.01)
  • decreasing MinCT (β = 1.33, P < 0.01).

Although ECD decreased with increasing disease severity and age, it remained relatively high, with only one eye showing an ECD < 2,000 cell/mm2.

Meaning: Increasing keratoconus tomographic severity results in a significant decrease in ECD; however, even in the most advanced stages, the ECD remains within physiological range.

When can we expect an update?

Considering the two phase 3 trials completed over the summer, there is likely additional data coming.

Plus: In June the company reported that it planned to file an NDA, though no specific timeline was provided, so stay tuned!